AcouShh Tech Acoustic Partitioning

In stock

SKU AB987625

As low as £247.00 £296.40

Quickest Available Delivery: 5 Days

 
Specifications

Specifications

Available Configurations Indoor / Outdoor
Indoor Panel Thicknesses 50mm / 100mm
Outdoor Panel Thicknesses 50mm / 100mm
Sound Absorption Classification Class A (tested perforated panel construction)
Sound Absorption Standard BS EN ISO 11654:1997
50mm Panel Sound Insulation Rw 32 (-3;-5) dB
100mm Panel Sound Insulation Rw 31 (-1;-4) dB
Sound Insulation Rating Standard BS EN ISO 717-1:2020
Core Material Rockwool stone wool
Core Density 120kg/m³
Standard Panel Dimensions 1196 x 3000mm / 573 x 3000mm
Maximum Stated Panel Length 4000mm
Alternative Panel Sizes Available on request
Panel Weight 15–22kg/m²
Panel Facing Options Perforated galvanised steel / Prefinished steel
Perforated Steel Profile R3T5
Panel Edge Profile Slip joint
Adhesive Two-part polyurethane
Indoor Panel Arrangement Vertical installation between existing building steelwork or a supporting frame
Outdoor Panel Arrangement Horizontal installation between steel support posts
Indoor System Components Acoustic panels, channels and cappings
Outdoor System Components Acoustic panels, channels, cappings, 100 x 100mm hollow-box sections, baseplates and fixings
Access Options Doors can be incorporated into outdoor configurations
Suitable Applications Factory divisions, machinery areas, production lines, test areas, plant rooms and external plant screening

Acoustic ratings refer to tested panel performance. Actual noise reduction depends on the completed installation, surrounding conditions and partition layout.

FAQs

FAQs

How does this acoustic partitioning control noise?

The steel-faced panels and stone wool core reduce sound transmission through the partition. When a perforated face is specified, the panels also absorb sound, helping reduce reflections around machinery and within the screened area.

What acoustic ratings do the 50mm and 100mm panels have?

The 50mm panel has a weighted sound reduction index of Rw 32 dB, while the 100mm panel is rated Rw 31 dB. Both thicknesses achieve Class A sound absorption in the tested perforated construction. These ratings describe the panels, rather than a guaranteed noise reduction for a completed installation.

Does the 100mm panel provide better noise control than the 50mm panel?

Not for every acoustic measure. The 100mm panel provides stronger sound absorption at 125 Hz and 250 Hz, but its weighted sound insulation rating is Rw 31 dB, compared with Rw 32 dB for the 50mm panel. Thickness selection should therefore consider the noise characteristics, not thickness alone.

Which way should the perforated panel face?

The perforated face should face the noise source. Where panels surround equipment, this means facing inwards towards the machinery so that sound can be absorbed within the screened area.

Can the system screen outdoor plant equipment?

Yes. The Outdoor configuration uses panels stacked horizontally between steel posts to screen chillers, heat pumps, air handling units and generators. It is available with either 50mm or 100mm acoustic panels.

Does Class A sound absorption mean the partition is fire-rated?

No. Class A describes the panel's sound absorption classification under BS EN ISO 11654:1997. It is not a fire-resistance rating.

Need help? Contact HERMEQ today.

Contact our team by email at sales@hermeq.com by phone on 0800 043 2520 or use our contact form. We would be delighted to help you.